Spacer chamber for predosed spray dispensers lespace 220ml adult spray lespace dead space 88ml with mask inhalation valve 2 exhalation valves magenta color code

vândut de liki24.co.uk

Detalii:

Area Description Spacer chamber for pre-dosed sprays. The use of a spacer chamber is recommended by international guidelines for the correct treatment of asthma. The spacer device is recommended for adequate drug deposition in the lower airways, as direct use of the inhaler, given the high drug exit velocity, would cause the nebulized drug to concentrate in the oropharynx. The space helps limit the side effects of oropharyngeal drug deposition and facilitates coordination between the act of inspiration and administration with the metered dose spray. Lespace simplifies therapy and ensures more effective treatment with all metered dose inhalers due to the adequate diffusion of the nebulized medication into the lower airways. Conical shape whose flow dynamics make a higher fraction of the drug available, increasing deposition in the lower airways. Ideal volume: The space reduces re-aggregation of nebulized drug particles due to the specially designed volume. Lamellar base: The space is equipped with slats with variable opening that adapt to the patients inhalation force, facilitating therapy. Anatomical and ergonomic mask that facilitates compliance even by the youngest. Excellent fit with minimal pressure. Valve system: the colored valve is a valuable aid for visual monitoring of breathing. Its movement is clearly visible, allowing proper coordination between drug administration and inhalation and allowing for counting of breaths. Universal base for all MDI inhalers (Metered Dose Inhalers). All models can be sterilized at 121°C. Reduced electrostatic charges. Textile cover for improved hygiene and safer transport. Durable and robust materials. Latex-free. How to use 1 - Before use, carefully inspect the product to ensure that it is assembled correctly and that there are no foreign objects or missing components. Remove any foreign objects before use; 2 - Before use, read the instructions provided with the MDI. Remove the cap from the MDI; 3 - insert the MDI into the butt; 4 - place the mouthpiece in your mouth and hold it between your lips; 5 - Press the MDI button and breathe in slowly through your mouth. Hold the mouthpiece in your mouth with your lips tightly closed for at least 5 breaths after pressing the inhaler. As you breathe in, air enters through the holes at the bottom, making it easier to inhale the nebulizer. Exhaled air exits through the exhalation valve; 6 - Wait 30 seconds before administering another dose of medication (repeat steps 4-5) or as directed by your doctor. Administer only one dose of medication at a time and follow your doctors dosing instructions. Cleaning If the device is used by the same person, clean it as directed. If the device is used by multiple people, in addition to cleaning, it should also be autoclaved at 121°C for 15 minutes after each use. The device can be sterilized without compromising its functional characteristics up to 20 times, after which it should be replaced. If deemed necessary, for thorough cleaning, the device can be boiled or washed in a dishwasher. A - the product must be cleaned following the instructions below before first use and then at least once a week: remove foundation and mask; B - Soak the parts for 15 minutes in warm water with a neutral disinfectant detergent. Shake gently; C - rinse with clean water; D - Shake off excess water as shown. Do not use dry cloths to dry the device components. Make sure the components are dry before reassembling; E - Replace the bottom and mask when the parts are completely dry and ready to use. Center the alignment arrow on the back component with the alignment notch on the body as shown. warnings Replace the product if a component is damaged. Some components, due to their size, can be swallowed by children. Do not leave these components unattended. Adult supervision is required at all times. Do not disassemble the product beyond the cleaning instructions. If you have any questions about the use of the product, consult your doctor or pharmacist. Clean the product only as directed in these instructions to ensure its effective functioning. Conservation When not in use, store the product in a clean container. Replace the product after 24 months of continuous use. Format - Yellow background: mask for children aged 2 to 6 years; - orange background: mask for children 0-2 years old; - magenta background: adult mask. Code 471351 (yellow background) 471352 (orange background) 471386 (magenta background)

Preț:

31.60 RON


Alte detalii:

Vânzător: Liki24.co.uk
Brand: N/a

De la același vânzător